{"id":5678,"date":"2025-03-07T14:13:48","date_gmt":"2025-03-07T06:13:48","guid":{"rendered":"http:\/\/192.168.1.196:164\/?p=5678"},"modified":"2025-04-11T16:55:08","modified_gmt":"2025-04-11T08:55:08","slug":"single-use-trocar-site-closure-device","status":"publish","type":"post","link":"https:\/\/weipumedical.com\/ko\/products\/single-use-trocar-site-closure-device\/","title":{"rendered":"Single Use Trocar Site Closure Device"},"content":{"rendered":"<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"800\" height=\"412\" src=\"http:\/\/192.168.1.196:164\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-14.jpg\"  class=\"wp-image-5679\" srcset=\"https:\/\/weipumedical.com\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-14.jpg 800w, https:\/\/weipumedical.com\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-14-600x309.jpg 600w, https:\/\/weipumedical.com\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-14-768x396.jpg 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" title=\"Single Use Trocar Site Closure Device\" alt=\"Single Use Trocar Site Closure Device\" \/><\/figure><\/div>\n\n\n\n<p>Multiple clamp shapes and sizes for selection<br>Capable of achieving liquid injection function<br>The handle conforms to ergonomics and drives smoothly<br>The guiding head can achieve fascia suturing positioning guidance<\/p>\n\n\n\n<p><\/p>\n\n\n<p>Model specifications:<\/p>\n<table border=\"1\" cellpadding=\"0\" cellspacing=\"0\" width=\"100%\" height=\"361\">\n<colgroup>\n<col width=\"148\">\n<col width=\"328\">\n<col width=\"221\">\n<col width=\"175\">\n<\/colgroup>\n<tbody>\n<tr>\n<td width=\"148\" height=\"35\" align=\"left\">Specifications<\/td>\n<td width=\"328\" height=\"35\" align=\"left\">OD(mm)<\/td>\n<td width=\"221\" height=\"35\" align=\"left\">L(mm)<\/td>\n<td width=\"175\" height=\"35\" align=\"left\">Pincerlike<\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-A-2.0x160<\/td>\n<td height=\"35\" align=\"left\">2.1<\/td>\n<td height=\"35\" align=\"left\">160<\/td>\n<td height=\"35\" rowspan=\"5\" align=\"left\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-27.jpg\"  width=\"79\" height=\"90\" title=\"Single Use Trocar Site Closure Device1\" alt=\"Single Use Trocar Site Closure Device1\" \/><\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-A-1.8x160<\/td>\n<td height=\"35\" align=\"left\">1.8<\/td>\n<td height=\"35\" align=\"left\">160<\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-A-1.6x160<\/td>\n<td height=\"35\" align=\"left\">1.6<\/td>\n<td height=\"35\" align=\"left\">160<\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-A-1.6x100<\/td>\n<td height=\"35\" align=\"left\">1.6<\/td>\n<td height=\"35\" align=\"left\">100<\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-A-1.4x160<\/td>\n<td height=\"35\" align=\"left\">1.4<\/td>\n<td height=\"35\" align=\"left\">100<\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-B-1.6x100<\/td>\n<td height=\"35\" align=\"left\">1.6<\/td>\n<td height=\"35\" align=\"left\">100<\/td>\n<td height=\"35\" align=\"left\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/2025\/03\/317823ff7efb55ad4287-1.jpg\"  width=\"82\" height=\"78\" title=\"Single Use Trocar Site Closure Device2\" alt=\"Single Use Trocar Site Closure Device2\" \/><\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-C-1.6x100<\/td>\n<td height=\"35\" align=\"left\">1.6<\/td>\n<td height=\"35\" align=\"left\">100<\/td>\n<td height=\"35\" align=\"left\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/2025\/03\/1a785dbb9ad69438fa26.jpg\"  width=\"93\" height=\"91\" title=\"Single Use Trocar Site Closure Device3\" alt=\"Single Use Trocar Site Closure Device3\" \/><\/td>\n<\/tr>\n<tr>\n<td height=\"35\" align=\"left\">WPFB-D-1.6x100<\/td>\n<td height=\"35\" align=\"left\">1.6<\/td>\n<td height=\"35\" align=\"left\">100<\/td>\n<td height=\"35\" align=\"left\"><img loading=\"lazy\" src=\"\/wp-content\/uploads\/2025\/03\/c20ef55b3b453743549e.jpg\"  width=\"162\" height=\"71\" title=\"Single Use Trocar Site Closure Device4\" alt=\"Single Use Trocar Site Closure Device4\" \/><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Note: The above are common specifications, please consult the manufacturer for more specifications.<\/p>\n<p>The C product comes with a liquid injection function, while the A, B, and D models can be customized with liquid injection options.<\/p>\n<p>&nbsp;<\/p>\n<p>Product features:<\/p>\n<p>1.Beautiful appearance and ergonomic design<br>\n2. All-in-one operation, fast and accurate thread holding, efficient and simple operation<br>3. The clamp does not clamp the wire, convenient wire feeding, hook line, easy for doctors to operate<br>4. lt can be sutured under the direct vision of laparoscope with high safety<br>5. lt can penetrate subcutaneous, muscle, fascia and peritoneum at one time, and the suture is tiahtand firm, which can effectively avoid the occurrence of postoperative hernia6.Single use to avoid cross-infection<\/p>\n<p>&nbsp;<\/p>\n<p>Mainly applicable to departments:<\/p>\n<p>Thoracic Surgery, Gastrointestinal Surgery, Hepatobiliary Surgery, Urology, Gynecology, etc<\/p>\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-full\"><img loading=\"lazy\" width=\"748\" height=\"271\" src=\"http:\/\/192.168.1.196:164\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-15.jpg\"  class=\"wp-image-5680\" srcset=\"https:\/\/weipumedical.com\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-15.jpg 748w, https:\/\/weipumedical.com\/wp-content\/uploads\/2025\/03\/8a993752e9658af10197-15-600x217.jpg 600w\" sizes=\"(max-width: 748px) 100vw, 748px\" title=\"Single Use Trocar Site Closure Device5\" alt=\"Single Use Trocar Site Closure Device5\" \/><\/figure><\/div>\n\n\n\n<p class=\"has-text-align-center\">High ligation of hernia sac under endoscopy<\/p>","protected":false},"excerpt":{"rendered":"<p>Multiple clamp shapes and sizes for selectionCapable of achieving liquid injection functionThe handle conforms to ergonomics and drives smoothlyThe guiding head can achieve fascia suturing positioning guidance Model specifications: Specifications OD(mm) L(mm) Pincerlike WPFB-A-2.0&#215;160 2.1 160 WPFB-A-1.8&#215;160 1.8 160 WPFB-A-1.6&#215;160 1.6 160 WPFB-A-1.6&#215;100 1.6 100 WPFB-A-1.4&#215;160 1.4 100 WPFB-B-1.6&#215;100 1.6 100 WPFB-C-1.6&#215;100 1.6 100 WPFB-D-1.6&#215;100 [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5835,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[175,3],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/posts\/5678"}],"collection":[{"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/comments?post=5678"}],"version-history":[{"count":3,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/posts\/5678\/revisions"}],"predecessor-version":[{"id":5859,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/posts\/5678\/revisions\/5859"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/media\/5835"}],"wp:attachment":[{"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/media?parent=5678"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/categories?post=5678"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/weipumedical.com\/ko\/wp-json\/wp\/v2\/tags?post=5678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}